MPRXCX® 150/250 (300) V
MPRXCX® 150/250V 2x0.75
Rif. Lynxeo 10193614
- Imballo: Bobina (100000m)
- Numero di anime: 2
- Diametro esterno min: 7,0 mm
- Diametro esterno max: 8,0 mm
- Peso approssimativo del cavo: 73 kg/km
MPRXCX® 150/250V 3x0.75
Rif. Lynxeo 10193615
- Imballo: Bobina (100000m)
- Numero di anime: 3
- Diametro esterno min: 7,3 mm
- Diametro esterno max: 8,3 mm
- Peso approssimativo del cavo: 85 kg/km
MPRXCX® 150/250V 5x0.75
Rif. Lynxeo 10210938
- Imballo: Bobina (100000m)
- Numero di anime: 5
- Diametro esterno min: 8,5 mm
- Diametro esterno max: 9,8 mm
- Peso approssimativo del cavo: 119 kg/km
MPRXCX® 150/250V 7x0.75
Rif. Lynxeo 10193620
- Imballo: Bobina (100000m)
- Numero di anime: 7
- Diametro esterno min: 9,0 mm
- Diametro esterno max: 10,4 mm
- Peso approssimativo del cavo: 142 kg/km
MPRXCX® 150/250V 12x0.75
Rif. Lynxeo 10199123
- Imballo: Bobina (100000m)
- Numero di anime: 12
- Diametro esterno min: 11,4 mm
- Diametro esterno max: 13,1 mm
- Peso approssimativo del cavo: 217 kg/km
MPRXCX® 150/250V 19x0.75
Rif. Lynxeo 10202495
- Imballo: Bobina (100000m)
- Numero di anime: 19
- Diametro esterno min: 13,7 mm
- Diametro esterno max: 15,7 mm
- Peso approssimativo del cavo: 339 kg/km
MPRXCX® 150/250V 37x0.75
Rif. Lynxeo 10237547
- Imballo: Bobina (100000m)
- Numero di anime: 37
- Diametro esterno min: 17,8 mm
- Diametro esterno max: 20,4 mm
- Peso approssimativo del cavo: 570 kg/km
Descrizione
Descrizione
Norme
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-360; IEC 60092-376
-
TestIEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
MPRXCX® type is used on board of ships for fixed installations complying with IEC 60092-352.
The good screening qualities of the braid also reduce radio interference and electrical influences to electronic installations. MPRXCX® type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements.
All materials used to manufacture this cable are halogen-free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships.
Design
1. Conductor
Stranded bare copper, class 2
2. Insulation
XLPE (cross-linked polyethylene)
3. Inner covering
(Filler, if necessary)
Lapped
5. Armour
Bare copper braid
6. Outer Sheath
Polyolefin SHF1
Colour: grey
Example of marking:
LYNXEO 279 MPRXCX Nber of cores & cross-section 150/250V 90C
IEC 60092-376 IEC 60332-3-22 Cat.A WW YYYY *CE* Manufacturing n° + metric marking
Core Identification
White with printed numbers